Prove Sismiche di Laboratorio

Classificazione Sismica Genova | Mappa delle Zone Sismiche in Liguria | Carta Sismica Liguria Prove Sismiche di Laboratorio

Prove Sismiche di Laboratorio

class=img-responsive

SEISMIC LABORATORY TESTS

 

Seismic tests carried out in 2010 at the ISMES / CESI-LPS Laboratory, Seriate (BG), according to the CEI 75-16, 1997-06, 75-16 standards "Classification and environmental conditions - Part 2: Environmental conditions appearing in nature - Earthquake vibration and shock "and the provisions of the DM January 14, 2008 and to the Circ. Min. 2 February 2009 n. 617.

Experimental verification of housing mod. Dim. 3982 x 3982 mm. in plan, 7340 mm. in height at the top of the cover panel. Structure consisting of 8 pillars, two decks and three-pitch roofing.

Seismic tests have shown the strength of the structure without the formation of collapse kinematisms, phenomena of local breaking of single elements, phenomena of near-flexional and torsional instability, finite deformations, for maximum values of acceleration equal to 0.552 g.

 

Prova sismica al CESI (BG) - Italia

Comportamento struttura con accelerazione massima pari a 0,46g

Prova sismica al CESI (BG) - Italia    

Comportamento struttura e tamponamento parziale con accelerazione massima pari a 0,55g

 

class=img-responsivePermanent static loads: complessivi 6500 kg, 4000 kg al primo livello, 2500 kg, massa totale della tavola vibrante circa 11000 kg.

Valore della forza statica assiale per i test di aclibrazione: 5000 kg.